The mecablitz 45 CL-4 is available in two versions:. mecablitz 45 CL-4-NC (with NiCad battery and battery charger) The NC version can be expanded to alkaline manganese battery operation by way of the battery holder 45-39 (available as an optional extra). mecablitz 45 CL-4-BAT (for operation with alkaline manganese batteries. Manual Metz 45 Cl-4 they are still great flashes for manual use (especially if you have a flash light 54MZ-4i, 45CL4 digital, 44MZ-2, 76MZ-5 digital) and the correct digital SCA 3000. I have a circa 1991 Metz 45 CL-4, the pre 'digital' version, which with an SCA only be used in Auto or Manual mode - so, it seemed ripe for a few modifications.

  • User manual Metz Mecablitz 45 CL-1. Free manual and PDF download. Got a question? Aks your question to other Metz Mecablitz 45 CL-1 users. We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it.
  • Metz MECABLITZ 45 CL-4 digital BASICKIT Instruction Manuals and User Guides. We have 2 Instruction Manuals and User Guides for MECABLITZ 45 CL-4 digital BASICKIT Metz. Metz MECABLITZ 45 CL-4 digital BASICKIT User Manual, 104 pages.
  • MECABLITZ 45 CL-4. Mode d’emploi. Operating instruction. Manuale istruzioni. Manual de instrucciones.

Just a note for all. The max sync speed is a function of the mechanics of the shutter, and not anything electronic It is the effectively the fastest time where the leading curtain can finish its travel before the trailing curtain has to follow. Ie the shortest time the complete sensor is exposed.

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets.. DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

Sponsored Links

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual METZ MECABLITZ 45 CL-4. We hope that this METZ MECABLITZ 45 CL-4 user guide will be useful to you.

Lastmanuals help download the user guide METZ MECABLITZ 45 CL-4.

Metz 45 Cl-4 Manual Pdf


You may also download the following manuals related to this product:

METZ MECABLITZ 45 CL-4 (962 ko)

Manual abstract: user guide METZ MECABLITZ 45 CL-4

Detailed instructions for use are in the User's Guide.

[. . . ] It is only natural that you can't wait to start using your flash unit. However, it will be to your advantage if you take the time to read these Operating Instructions beforehand so that you are completely familiar with its operation. This flash unit is suitable for: · All cameras with a synchronising socket in conjunction with the supplied synchronising cable 45-472). All cameras with a flash shoe and a hot-shoe contact in conjunction with the supplied synchronising cable 45-54 (optional extra). [. . . ] The flash unit will then be switched on and off with the switch on the Power Pack (see Operating Instructions for the Power Pack). It is operated with To protect theaflash unit from overheating whenrecycle time during a Power Pack, monitoring circuit lengthens the intensive use!Ensure that all affected devices are switched off before connecting and disconnecting the connecting cable or the Power Pack! Ting mark for aperture pre-selection to the required auto working aperture, TTL mode or M manual mode, or a manual partial light output. A flash can be fired with the manual firing button when flash readiness is established. Equip the flash unit with the connecting cable SCA 30453) and appropriate adapter from the SCA 3002 system and connect to the camera. On the flash unit, set any auto working aperture with the setting mark for aperture pre-selection . Lightly touch the camera's shutter release so that data can be exchanged between the camera and the flash unit. When the camera's shutter release is lightly touched the flash unit automatically takes over the data for the aperture and ISO setting from the camera. The values for auto working aperture and ISO manually adjusted on the flash unit are irrelevant in this context. With fill-in flash) continue depressing the 'Mode' key until only 'A' is displayed on the display window. This means that light measurement also takes mounted filters into account. When an adequate amount of light has been reached the camera's electronic circuit switches off the flash by way of the SCA adapter. Equip the flash unit with the connecting cable SCA 30453) and a suitable adapter from the SCA 3002 system and connect to the camera. Adapters of the SCA 300 system can be connected to the flash unit with the connecting cable SCA 30453) or the connecting cable SCA 300A. The maximum flash range can be read off directly from the aperture calculator under the f-stop when the ISO value of the camera or film has been manually set on the flash unit. The subject should be located in the middle third of the indicated range to give the electronic circuit leeway for compensation. Aperture or ISO The TTL flash mode tovalue does not have to be set on the flash unit for the function!In TTL flash mode with preflash the reflective properties of the subject are established with one or more preflashes prior to exposure and evaluated by the camera's electronic circuit. The distance data from the camera's AF system can be additionally taken into account. Light output control by the camera's electronic system is via an adapter from the SCA 3002 system. These are further developments of the standard TTL flash mode which is not supported by these cameras. [. . . ] Guide numbers at ISO 100/21°: in the metric system: 45 in the imperial system: 148 Flash modes TTL, TTL modes with preflash (see Table 1), Auto Mode A, Manual Mode M, high-speed synchronisation HSS Manually adjustable auto apertures: f2. 400 with Power Pack P76 (all at full light output) Recycling time: · With Power Pack P76 (all at full light output) Flash coverage Main reflector, as of 35 mm (35 mm format) . In mm (w x h x d) Flash unit 92 x 247 x 102 Weight: Flash unit without power sources: approx. 11 Distance range with wide-angle diffuser These table does not apply to bounced flash. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE METZ MECABLITZ 45 CL-4

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets..
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on 'Download the user Manual' at the end of this Contract if you accept its terms, the downloading of the manual METZ MECABLITZ 45 CL-4 will begin.

Advertising

ķ

53

of 2 °C to 8 ° C (e.g. in a refrigerator).

• Keep the battery pack charged and recharge it at suitable intervals.
• Protect the battery pack against frost and heat!

4.1.2 Connecting the charger to the mains

The charger is supplied complete with interchangeable adapters for different
mains sockets (Fig. 5). To change the adapter, disconnect the charger from
the mains socket, release the currently installed adapter by pressing the key a
and at the same time pull off the adapter y (Fig. 6).
With no adapter fitted, the battery charger can be connected to a mains
socket with the aid of a mains cable (not included) which is inserted into the
integrated mains connection socket (Fig. 7).

4.1.3 Charging the batteries

The NiMH battery pack 45-56 can be charged either in the flashgun or
separately. If it is charged in the flashgun, the flashgun must be switched off !

DO NOT switch on the flash unit while the battery is being charged in
the flash unit! The battery must only be charged with the original Metz

battery charger envisaged for this purpose! DO NOT use any other
charger!

The battery pack is exhausted if the recharging time after a full-power flash
(e.g. in manual flash mode M) exceeds about 60 seconds.
The charging operation is monitored by a microcontroller in the battery char-
ger. When the battery pack is fully charged, the charging operation is termi-
nated automatically and the battery charger switches to trickle-charge mode.

You can leave the battery pack connected to the charger in order to
ensure continuous readiness. However, if you do not intend to use
the battery pack for a long period, you should disconnect it from the
charger.

For safety reasons, the temperature of the battery pack is monitored during
charging and the charging time is also limited by a timer. The charging time
is about 2.5 hours for a fully discharged battery pack and correspondingly

shorter for a partially discharged battery pack.
• Connect the battery charger 970 to a mains outlet socket and to the

battery pack (the connector for the charger is on the bottom of the
pack). The charging operation starts automatically. The status of the
battery charger is indicated by a two-colour LED.

> LED lights with red light: the battery pack is being charged.
> LED lights with green light: the battery pack has been fully charged

and the charger has switched to trickle-charge mode.

Identifying a discharged battery pack 45-56:
move the ribbed slide on the battery cover to the black position.
Identifying a fully charged battery pack 45-56:
move the ribbed slide on the battery cover to the white position.

4.2 Operation with Power Pack P50 or P76

If the number of flashes and recycling times are not sufficient for your given
application, then the flash unit can be powered with the Power Pack P50 or
P76 (optional extra). The Power Pack is connected to the flash unit via the
socket

ቦ with the V50 or V76 connecting cable (optional extra). This does

not require the use of the battery holder 45-39 or the NiMh Battery
Pack 45-56 inside the flash unit.

A loaded battery holder or battery pack can remain in the flash unit.

To connect the Power Pack or the connecting cable V50 or V76 to the flash
unit the main switch

Metz 45 Cl-4 Flash Manual

ቪ of the flash unit must be pushed down into its lower

position (OFF).
The flash unit will then be switched on and off with the switch on the Power
Pack (see Operating Instructions for the Power Pack).

To protect the flash unit from overheating when it is operated with a
Power Pack, a monitoring circuit lengthens the recycle time during

Manual

intensive use! Ensure that all affected devices are switched off before
connecting and disconnecting the connecting cable or the Power Pack!

Aldi walk in greenhouse user manual.

Metz 45 Ct 4 Manual

Metz 45 Cl-4 User Manual

704 47 0126.A5 45 CL-4 digi 01.02.2007 13:13 Uhr Seite 53

Advertising
This manual is related to the following products:

Ladeset B46, Ladeset B47, MECABLITZ 45 CL-4 digital BASIC_KIT

Metz 45 Cl-4 Digital Manual

Popular Brands

Metz 45 Cl 4

Popular manuals
Comments are closed.