Sep 11, 2016 This Whynter ARC-12S 12,000 Btu Portable Air Conditioner draws warm, humid air from the room and converts it into cool and fresh air. The sleek, platinum-colored mobile unit features auto drain technology for controlling condensation, an easy-to-install single hose venting system, and three operational modes: cooling, fan only, and dehumidifying.cooling power:12000. Page 1 WHYNTER ECO-FRIENDLY 14,000 BTU PORTABLE AIR CONDITIONER MODEL#: ARC-14S Instruction Manual Congratulations on your new WHYNTER product. To ensure proper operation, please read this Instruction Manual carefully before using this product. Keep this manual in.
In this user guide to obtain the very best performance from your portable air conditioner and take full advantage of the many features your portable air conditioner offers you. We trust that your Whynter air conditioner will provide the performance and reliability that we stand for. Please keep this user manual in a safe place for future reference. Whynter is going GREEN! With this new Eco-friendly CFC free, lead free and high energy efficiency portable air conditioner, you can stay cool while keeping with better environmental standards and reducing energy consumption. This Whynter GREEN ARC-14S portable air conditioner features the ECO-FRIENDLY CFC free GREEN R-410A refrigerant and lead free RoHS compliant components.
Instruction Manual
Congratulations on your new WHYNTER product. To ensure proper operation, please read this Instruction
Manual carefully before using this product. Keep this manual in a safe place for future reference.
TABLE OF CONTENTS
INTRODUCTION | 3 |
SAFETY PRECAUTIONS | 4-5 |
IDENTIFICATION OF ACCESSORIES | 6 |
IDENTIFICATION OF PARTS | 7 |
OPERATING YOUR AIR CONDITIONER | 8 |
INSTALLATION INSTRUCTIONS | 9-10 |
AIR FILTERS INSTALLATION | 11 |
OPERATION INSTRUCTIONS | 12-13 |
WATER DRAINAGE | 13 |
REMOTE CONTROL | 14 |
CARE AND MAINTENANCE | 15 |
TECHNICAL DATA | 16 |
TROUBLESHOOTING | 17-18 |
WARRANTY INFORMATION | 19 |
2 P a g e
Thank you for choosing the Whynter portable air conditioner. Please follow the instructions provided in this user guide to obtain the very best performance from your portable air conditioner and take full advantage of the many features your portable air conditioner offers you. We trust that your Whynter air conditioner will provide the performance and reliability that we stand for.
Please keep this user manual in a safe place for future reference.
DISPOSAL
This symbol on the product or its packaging indicates that the appliance cannot be treated as normal domestic trash, but must be handed in at a collection point for recycling electric and electronic appliances. Your contribution to the correct disposal of this product protects the environment. Further information about the recycling of this product can be obtained from your local municipal authority.
3 P a g e
Your safety and the safety of others are very important to us.
To reduce the risk of fire, electrical shock or injury when using your appliance, follow these basic precautions.
SAFETY PRECAUTIONS
Before the portable air conditioner is used, it must be properly positioned and installed as detailed in this manual.
Do not under any circumstances cut or remove the third (ground) prong from the power cord.
Make sure this unit is connected to a correctly grounded power supply outlet. Do not use an extension cord or power strip.
The power cord is UL listed. It has a built-in L.C.D.I. (leakage, current, detection, interruption) circuit breaker for added safety. If the power supply is interrupted, press the reset button to reconnect the unit to power source.
It is recommended to use a separate circuit that its size should be 15 Amps for the air conditioner.
Do not use an excessively wet cloth, industrial solvents, oil-based products to clean this portable air conditioner.
To avoid the risk of shock, the product should never be used in bathrooms, shower rooms, or in any other steamy or wet areas.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliances.
Do not repair, disassemble and/or modify the unit by yourself.
Always turn off the portable air conditioner when cleaning the air filter, and transporting.
Do not turn this unit on and off by plugging and unplugging. Always use the ON/OFF switch.
Transport the unit in an upright position only, or leave it in an upright position for at least 2 hours before first use.
Ensure curtains or other objects are not obstructing the air inlet filters.
Do not bend or crush the exhaust hose while in use.
Always allow at least 20” of clearance around the unit for ventilation. Do not use this unit inside closets, cabinets and/or cramped spaces between furniture.
This unit is optimized to operate in an ambient temperature of 64°F – 95°F.
This unit must be installed in an area protected from the element, such as wind, rain, water spray or drips.
The unit should not be located next to ovens, grills or other sources of high heat.
Always place the unit on even and hard and level surface.
Do not sit or place objects on the unit.
Do not allow children to climb, stand or hang on the unit. The air conditioner could tip over and get damaged and/or seriously injure somebody.
Keep fingers out of the air intakes and air outlets.
The unit is an electrical appliance. To avoid injury from electrical shock do not operate it with wet hands, while standing on a wet surface or while standing in water. Do not use it in outdoors or in wet conditions.
When positioning or moving the unit, ensure it is not turned upside down or greater than 45° or more off level.
This unit is designed for household, non-commercial use only. Any other use will void the warranty.
Do not plug into the power outlet before set up is completed.
Do not operate this unit without the air filter(s).
Do not use harsh chemicals to clean the filter(s). Dry thoroughly before inserting the filter(s) into the unit.
Do not add extra length to the exhaust hose by more than a total length of 9’. This will reduce the cooling efficiency of the portable air conditioner.
At the end of each season, all water must be drained from the unit and filter(s) must be cleaned before storage.
THE MANUFACTURER DISCLAIMS ANY RESPONSIBILITY IF THE ABOVE INSTRUCTIONS
ARE NOT FOLLOWED.
OPERATING CONDITION
MODE | ROOM TEMPERATURE |
COOL | Higher than 64°F |
DRY | Higher than 60°F |
Your portable air conditioner is supplied with a Leakage-Current Detection and Interruption (LCDI) plug. This plug reduces the risk of fire due to arcing faults in the power supply cord. Please follow the instructions below to ensure that LCDI plug works properly.
1.Plug the power cord to a grounded wall outlet. Do not plug to a power strip or extension cord.
2.Press the TEST button on the plug. This should trip the plug and cut the power to the air conditioner. If the plug does not trip and the unit comes on, please contact technical support.
3.Press the RESET button to start the air conditioner.
4.Do NOT use the TEST and RESET buttons to turn the air conditioner on and off.
IDENTIFICATION OF ACCESSORIES
IMAGE | ACCESSORY NAME | QUANTITY |
Intake and Exhaust hose | 2 pieces | |
Fixture | 2 pieces | |
Screws | 8 pieces | |
Hose connector | 4 pieces | |
1 set | ||
Window slider kit | ||
Cover | 2 pieces | |
Remote control | 1 piece | |
Optional 3M™ Antimicrobial filter (sold | 1 piece | |
separately) |
IDENTIFICATION OF PARTS Front
1. Air vent
2. Control panel
Rear
3. Evaporator air intake / air filter
4. Air intake hose
5. Air exhaust hose
6. Casters
7. Drain port
8. Power cord
7 P a g e
OPERATING YOUR AIR CONDITIONER
Before you begin, thoroughly familiarize yourself with the control panel, remote control and all of the functions. Follow the symbol for the desired function. The unit can be controlled by the unit control panel alone or with the remote control.
CONTROL PANEL
Power Control | Timer |
Turns the unit on and off. | Turns the timer function on and off. |
Warning Light | Timer / Temperature Set Control |
Condensation water may accumulate in the unit. If the | Adjusts set thermostat temperature and timer. |
internal reservoir becomes full, the warning light and the | The display temperature is the set temperature. |
STOP light will come on and the unit will stop until the | |
water is drained. | NOTE: This unit is capable of displaying set temperature |
in Fahrenheit or in Celsius. To convert from one to the | |
other, press and hold the Up and Down buttons for 3 | |
Mode Control | seconds. |
Controls the 3 function modes: COOL, DEHUMIDIFY | |
and Fan only. | |
Fan Speed Control | |
Controls the 3 fan speeds: High, Medium & Low. | |
NOTE: Unit does not need to be vented in Fan mode |
INSTALLATION INSTRUCTIONS
Location
The air conditioner should be placed on a hard and level surface strong enough to support the unit. The unit has casters and it should only be rolled on smooth, flat surfaces. Use caution when rolling on carpet surfaces. Do not attempt to roll the unit over objects.
Never place any obstacles around the air inlet or outlet and allow at least 20 inch of clearance for efficient air-conditioning.
Intake and Exhaust hose Installation
When you use this air conditioner unit, hot air must be exhausted out of the room to complete the air exchange of the condenser. When the unit is operating in DEHUMIDIFYING or FAN only mode, no exhaust is required.
1.Pull out about 6” of one end of the hoses.
2.Attach the hose connectors to the hoses by turning clockwise.
3.Align the slots on the hose connector to the tabs on the air intake / outlet and snap the hose to the unit.
EXHAUST
INTAKE
4.Only extend the exhaust hoses to the necessary length. We do not recommend extending the exhaust hose more than 9' long. Additional 4’ exhaust hose sold separately.
*If you are interested in purchasing optional accessories, please contact info@whynter.com for retail sales information.
9 P a g e
Window kit Installation
When you use this air conditioner unit, hot air must be exhausted out of the room to complete the air exchange of the condenser. When the unit is operating in dehumidifying and fan-only mode, no exhaust is required.
Your window kit has been designed to fit most standard vertical and horizontal windows. However, it may be necessary for you to modify the installation procedures for your window.
NOTE: If your window opening is less than the mentioned minimum length of the window slider kit, cut the slide bar with hole to fit window opening. Never cut out the hole on the window slide bar.
NOTE: When using the window kit on a window or sliding door it will cause the window or sliding door not to be properly closed and locked. Additional security measurements may be needed.
1.Open window approximately 5”.
2.Adjust the length of the window bars to the same length and width of the opening of the window. Cut the window piece if necessary to fit the length of your window.
3.Insert the fixtures through the back grooved side of the window slide bar with holes. Line up the 4 holes and tighten the fixtures with 4 screws
from the front. Fig 1.
4.Close the window on the window slide bars. For long
term installation, you may screw the window kit into your window frame.
5.Move the unit to the window, extend the hoses and attach the other end of the hoses to the window slide bar.
6.Align the slots on the hose connectors to the tabs on the fixtures and snap the hoses to the window slide bar.
Figure 1
10 P a g e
AIR FILTERS INSTALLATION
Your Whynter portable air conditioner is equipped with a washable Pre-Filter and an Activated Carbon Filter.
The washable Pre-Filter removes large particles such as dust, pet hair and dander.
The Activated Carbon filter is designed to remove smoke and other odors. It is recommended you replace the Activated Carbon filter every 2-3 months or as needed. Follow the steps below to install the filters.
WARNING: NEVER OPERATE THE AIR CONDITIONER WITHOUT THE PRE-FILTER
1. Pull up the pre-filter frame
2.Remove the Pre-Filter from the filter frame.
3.Place the Activated Carbon filter on the Pre-Filter.
4.Reattach the filter frame.
5.Insert the assembled filter frame into the unit.
An optional 3M™ Antimicrobial Filter can also be purchased to replace the activated carbon filter. The 3M™ Antimicrobial Filter has an antimicrobial agent helps inhibit the growth of mold and mildew on the filter. This filter is electrostatically charged for enhanced particle capture and retention.
**If you are interested in purchasing optional accessories, please contact info@whynter.com
for retail sales information. | 11 P a g e |
OPERATION INSTRUCTIONS
BEFORE USING YOUR PORTABLE AIR CONDITIONER
Remove the exterior and interior packaging.
Before connecting the unit to the power source, let it stand upright for approximately 4 hours. This will reduce the possibility of a malfunction in the cooling system from handling during transportation.
SWITCHING ON/OFF THE AIR CONDITIONER
The unit can be switched ON or OFF by pressing the Power button on the control panel or the Power button on the remote control.
COOLING MODE
In this mode, the air conditioner cools and dehumidifies the room. To activate this function mode, press the Mode Control button until the indicator comes on. When the cooling mode is set, the compressor will start in approximately 3 minutes.
NOTE: In cooling mode, hot air is exhausted from the outdoor exhaust port and the exhaust hose must be connected to exhaust out the hot air.
The temperature setting range of this air conditioner is from 61°F to 89°F. To set the temperature, press the + or - buttons. This air conditioner has a 5°F temperature cushion which if the set temperature is within 5°F of the ambient temperature, the unit runs on fan only mode. This saves energy and prolongs the life of the compressor of the air conditioner. Once the set temperature is achieved, the fan runs continuously.
To set the fan speed, press the Fan Speed button. In cooling mode, the difference in noise level between the 3 fan speeds is not very noticeable when the compressor is on. Try setting the unit to Fan only mode, you should be able to hear the difference between high and low fan speed settings.
DEHUMIDIFYING MODE
Whynter Portable Air Conditioner Owner's Manual
In this mode, the air conditioner only dehumidifies the room, the compressor will activate intermittently depending on the ambient temperature and the fan speed is set to LOW. To activate this function mode, press the Mode Control button until the indicator comes on. Please note that when switching function mode, there will be an approximately 3 minute transition time. In dehumidifying mode, do not connect the exhaust hose and let the warm air return to the room. If room temperature is higher than 77°F, the fan speed can be adjusted. If room temperature is lower than 77°F, the fan speed is set at Low.
NOTE: When using the Dehumidifying mode, the air exhaust hose should not be vented to the outside. If the warm air is exhausted to the outside, cooling may occur. Additionally, you must manually drain the water from the unit.
FAN ONLY MODE
In this mode, only the fan of the air conditioner runs and circulates the air in the room. To activate this function mode, press the Mode Control button until the indicator comes on. In this function mode, the temperature cannot be set. Subsequently, set the desired fan speed by pressing the Fan Speed button. Fan Only mode requires that the exhaust hose be removed.
NOTE: The unit does not need to be vented in Fan Only mode.
TIMER (DELAYED SWITCH ON / OFF) FUNCTION
This function mode enables a delayed switch ON or delayed switch OFF of the air conditioner. The time (hours) delay can be set, enabled and disabled. The timer is adjustable between 1-24 hours.
SETTING SWITCH OFF TIMER
Download Complete Service Repair Manual for Kubota ZD1211, ZD1211R, ZD1211L, ZD1211RL Tractor. This Factory Service Repair Manual offers all the service and repair information about Kubota ZD1211, ZD1211R, ZD1211L, ZD1211RL Tractor. ZD1200 Series. ZD1211-60 / ZD1211-72 With a 24.8 HP diesel engine and wider mower deck, the ZD1200 can get the job done with speed and efficiency. Delivering superior cutting performance with the ACS Kubota PRO deck designed for more efficient power consumption and durability. Choose between side or rear discharge; available in 60” or 72. View and Download Kubota ZD1011 operator's manual online. ZERO TURN MOWER. KUBOTA recommends the use of a Roll Over accident. The owner/user can prevent and is responsible Protective Structures (ROPS) and seat belt in almost for accidents or injuries occurring to. MACHINE MODEL; Kubota ZD1211, ZD1211R, ZD1211L, ZD1211RL9Y111-13443 service manual PDF Download. This manual may contain attachments and optional. Workshop manuals, service manuals, repair manuals, parts. Kubota B3030 Workshop Manual - Download. Kubota B5100-B6100-B7100 Owners Manual - Download. Kubota ZD1211 ZD1211R ZD1211L ZD1211RL - Download. Kubota GF1800-R-2 MODELES GF1800E-R-2 - Download.
With the air conditioner operating in any function mode, press the Timer Control button. Then set the desired time delay OFF hours by pressing the + or - buttons. When the delay time set has elapsed, the air conditioner switches off.
SETTING DELAYED SWITCH ON TIMER
With the air conditioner is off, press the Timer Control button. Then set the desired time delay ON hours by pressing the + or - buttons. When the delay time set has elapsed, the air conditioner switches on.
AUTO RESTART
In the event of a power outage, the air conditioner restarts at the previously set function mode and settings when power is restored.
NOISE LEVEL
Portable air conditioners may make sounds that are not familiar to you. The sounds listed below are normal. Noise reflecting off hard surfaces such as a floor or wall can make the sounds seem louder than they actually are.
The compressor may make a pulsating or high-pitched sound.
Water running from the evaporator to the water tank may make a splashing sound.
Refrigerant flowing may make a gurgling sound.
Fan sound may come from front and back air vents.
WATER DRAINAGE
During the process of cooling, some water will be extracted from the air into the unit. Most of this water is used to cool and exhausted to the outside. If the unit is operated in high humidity or low temperature environment, water will collect in the reservoir inside the unit. If the reservoir is full, the compressor will stop. To continue the cooling function, please drain the water.
1.Turn off the unit.
2.Position a flat container or dish under the drain plug.
3.Remove the drain plug and the condensed water will drain out automatically.
4.Once all the condensed water is drained, replace the drain plug into the drain firmly.
REMOTE CONTROL
The portable air conditioner can be switched on by the remote control.
NOTE:
Other appliances in the same room controlled by a remote control (TV, radio, stereo, etc.), may cause interferences.
Electronic and fluorescent lamps may interfere with the signal transmissions between the remote control and the air conditioner.
Remove the batteries if the remote control is not used for long periods.
INSTALLING BATTERIES
Only use two AAA 1.5V Batteries in the remote control.
Always change both batteries at the same time.
To insert the batteries, open the flap on the back of the remote control by sliding if off. Strictly adhere to the polarity signs on the bottom of the battery housing, close the flap once the batteries have been inserted.
CARE AND MAINTENANCE
IMPORTANT:
Switch off the air conditioner and disconnect the plug from the power outlet
Drain water by removing the drain plug.
Always transport the air conditioner in an upright position only.
CLEANING THE PRE-FILTER
To ensure the air intake is filtered properly and to assure that your air conditioner runs efficiently, it is recommended to clean the Pre-filter at least once every two weeks.
Switch off the air conditioner and pull out the filter frame from the unit.
Remove the Activated Carbon filter from the Pre-filter.
Use a vacuum cleaner or tap lightly to remove loose dust and dirt from the Pre-filter. Then rinse it thoroughly under warm or cold running water (no hotter than 100F.)
Dry thoroughly before re-inserting the filters.
NOTE: The Activated Carbon filter is not washable. It should be replaced every 2-3 months or as
needed.
WARNING! Never operate the air conditioner without the filter in place.
CLEANING THE AIR CONDITIONER
Always switch off the air conditioner and disconnect the plug from the power supply outlet before cleaning the air conditioner.
Whynter Portable Air Conditioner Manual
Use a soft damp cloth to wipe the body of the unit.
Never use harsh chemicals, oil-based products, detergents, chemically treated cloths or other cleaning solutions. These could possibly damage the body of the air conditioner.
END OF SEASON STORAGE
Switch off the air conditioner and disconnect the power plug from the power supply outlet before cleaning the air conditioner.
Clean the air filters.
Drain the condensed water COMPLETELY.
On a warm day, turn on the Fan only mode for half a day so that the inside can dry out completely.
Wrapped the power cord and bundle it with the tape.
Remove the batteries from the remote controller.
Disconnect the exhaust hose and cover the window / wall hole with the cover.
It is recommended that the air conditioner be put back into its original carton for storage.
To avoid damage to the unit, please leave the hose connectors in place or slightly turn, push and gently pull the connectors off.
TECHNICAL DATA
Model | ARC-14S |
Cooling capacity | 14,000 BTU |
Power supply | 115v/ 60Hz |
Maximum power input | 1250 Watts |
Maximum input | 10.8 Amps |
Dehumidifying capacity | 101 Pts / Day |
Thermostat | 61°F to 89°F |
Refrigerant | R-410A |
Air flow (max.) | 360 m3/ Hour |
Fan speeds | 3 (H, M, L) |
Exhaust hose length | 49” |
Unit Dimensions | 19” W x 16” D x 35.5” H |
Unit Weight | 80 lbs |
TROUBLESHOOTING
Problem | Possible Causes | Solutions |
The portable air | Power failure / outage. | Restore the power supply. |
conditioner does not | ||
turn on | The automatic switch, line | Flip the switch / change the fuse / turn the breaker |
fuse, or breaker has been | back on. Also note that you may have too many | |
tripped. | appliances drawing power on one circuit, you may | |
need to move the other appliances to another | ||
circuit. | ||
The power supply voltage is | Move the unit onto another circuit with the correct | |
too low. | voltage. | |
The power cord is damaged. | Contact Whynter Service Department. Only | |
authorized personnel should replace damaged | ||
power cord or power plug. | ||
The L.C.D.I. power plug for | Press the Reset button on the L.C.D.I. power plug. | |
the unit is tripped. | ||
The internal water reservoir | Drain water from the air conditioner. | |
is full. | ||
Possible loose connection | Contact Whynter Service Department | |
Internal fuse has blown | ||
The unit turns on but | The room temperature is | This unit is designed to work in ambient |
the compressor does | outside of the operational | temperatures of 64°F to 95°F. |
not turn on (the fan | tolerances of the unit. | |
runs but the unit is not | ||
cooling) | The Cooling mode is not on. | Press the MODE button until the COOL light is |
shown on the display. | ||
The compressor has not | Give the compressor 3 minutes to turn on after the | |
turned on yet because of its | Cooling mode has been selected. | |
time delay. | ||
The set temperature is too | Set the air conditioner to a lower temperature. It is | |
high. | recommended to set the temperature to at least | |
5°F of the ambient temperature. | ||
The internal water reservoir | Either manually drain the water by removing the | |
is full. | drain plug or allow the unit to exhaust the water | |
itself by running the fan only mode. Then cooling | ||
will resume. |
The air coming out of | The filters are dirty or | Clean the air filters. |
the unit is not very | obstructed. | |
cold, or the airflow | The air intake or exhaust is | Make sure there is at least 20' of clearance from |
volume is weak | obstructed. | the air intake. Make the length of the exhaust hose |
is as short as possible. | ||
The unit is set in DRY or | Set the unit to the cooling mode. | |
FAN mode. | ||
The unit is set to low fan | Set the unit to a higher fan speed. | |
speed. | ||
The unit has worked for | Windows or doors are open. | Close all windows and doors. |
a long time, but the | There are too many people | You may need additional cooling or another air |
room is not cold | ||
in the room. | conditioner. | |
enough | ||
There is direct sunshine into | Close curtains or blinds and try to minimize the | |
the room. | amount of direct sunlight into the room. | |
The room is a kitchen or | You may need additional cooling or another air | |
with many heat-producing | conditioner. | |
appliances | ||
There is a server in the | You may need additional cooling or another air | |
room. | conditioner. | |
The room is too large. | You may need additional cooling or another air | |
conditioner. | ||
The unit is very noisy | The unit is not level. | Make sure the unit is on hard, level and stable |
surface. | ||
The surface underneath the | Move the unit to a location with a level and hard | |
unit is uneven. | floor. | |
Low power voltage. | Make sure the wall outlet and support the required | |
power consumption of the air conditioner and do | ||
not use an extension cord. | ||
The unit leaks water | The unit is tilted or not | Make use the unit is leveled. |
leveled | ||
The water tank is full. | Drain water from the drain plug at the back of the | |
air conditioner. | ||
The unit needs to be | The humidity in the area | Remove the intake hose if the outside humidity is |
may very high | high or it is raining | |
drained too often | ||
Possible loose connection | Contact Whynter Service Department | |
Fan speed cannot be | Fan speed differences are | The fan speed difference is not very noticeable |
not very noticeable | when the compressor is on. Try setting the unit to | |
changed | ||
Fan only mode, you should be able to hear the | ||
difference between high and low fan speed | ||
settings. |
ONE YEAR LIMITED WARRANTY & THREE YEAR WARRANTY ON COMPRESSOR
This WHYNTER portable air conditioner is warranted, to the original owner within the 48 continental states, for one year from the date of purchase against defects in material and workmanship under normal use and service. Should your WHYNTER portable air conditioner prove defective within one year from the date of purchase, return the defective part or unit, freight prepaid (within two months of purchase; after two months to one year, customer will be responsible for freight cost to Whynter’s service department), along with an explanation of the claim to Whynter LLC. Please package the portable air conditioner carefully in its original packaging material to avoid damage in transit. Please retain the original box and packaging material. Under this warranty, Whynter will repair or replace any parts found defective. This warranty is not transferable. After the expiration of the warranty, the cost of labor and parts will be the responsibility of the original owner of the unit.
THIS WARRANTY DOES NOT COVER:
Acts of God, such as fire, flood, hurricanes, earthquakes and tornadoes.
Damage, accidental or otherwise, to the air conditioner while in the possession of a consumer not caused by a defect in material or workmanship;
Damage caused by consumer misuse, tampering, or failure to follow the care and special handling provisions in the instructions.
Damage to the finish of the case, or other appearance parts caused by wear.
Damage caused by repairs or alterations to the product by anyone other than authorized by the manufacturer.
Freight and Insurance cost for the warranty service.
DISCLAIMER OF IMPLIED WARRANTIES; LIMITATION OF REMEDIES
CUSTOMER'S SOLE AND EXCLUSIVE REMEDY UNDER THIS LIMITED WARRANTY SHALL BE PRODUCT REPAIR OR REPLACEMENT AS PROVIDED HEREIN. CLAIMS BASED ON IMPLIED WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED TO ONE YEAR OR THE SHORTEST PERIOD ALLOWED BY LAW, BUT NOT LESS THAN ONE YEAR. WHYNTER SHALL NOT BE LIABLE FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES SUCH AS PROPERTY DAMAGE AND INCIDENTAL EXPENSES RESULTING FROM ANY BREACH OF THIS WRITTEN LIMITED WARRANTY OR ANY IMPLIED WARRANTY. SOME STATES AND PROVINCES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, OR LIMITATIONS ON THE DURATION OF IMPLIED WARRANTIES, SO THESE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO YOU. THIS WRITTEN WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS. YOU MAY ALSO HAVE OTHER RIGHTS THAT VARY FROM STATE TO STATE.
To obtain service or information, contact Whynter LLC via email at service@whynter.com or call
866-WHYNTER.
Product contents and specifications may change without notice.
Copyright © 2014 Whynter LLC
www.Whynter.com
This manual is encoded in PDF file format
The PDF (Portable Document Format) was created in the early 1990’s as a brand new way for computer users to share documents between each other, especially if one person has a PC and the other a Mac. The shared PDF will display exactly the same on both computers.
PDF was created by Adobe and is no maintained by the International Organisation for Standardisation (ISO). It is a very interactive format and can contain buttons, links, audio, video, form fields, business logic and even electronic signatures. It can capture fonts, images as well as document texts and can also format documents from many different programs.
Most PDF viewers or the software used to view the PDF is provided free of charge. There are many options available including Scribus, pdfTex, Adobe InDesign, Adobe Illustrator as well as Google Docs. The most popular however is Acrobat Reader DC.
Why we provide Whynter Air Conditioner manuals in PDF?:
- · PDF’s are incredibly convenient and are easy to open and read by everyone, regardless of whether they have a PC or Mac.
- · A PDF can be compressed into a file size that is easy to email while still maintaining the quality of the images.
- · A PDF file can be made incredibly secure as you can set up passwords, digital signatures and even watermarks.
- · A PDF allows you input many different types of content including images, animations, 3D models, hyperlinks and buttons.
PDF’s do have their drawbacks such as:
- · PDF’s can often be difficult to edit or to extract information from as it’s original intention was to make the exchange of documents easier.
- · There are different types of PDF’s, especially when searching or extracting information.
If you have a document that you would like to convert into a PDF, there are many sites online that will do the conversion for you for free and very quickly. The same is true if you are looking to convert from PDF format into a different format. This is often a much easier way to edit a PDF.